Custom FRP Digital Radiography Housings

Fiberglass covers form the outer faces of a radiography unit's head, column and separate control box. A broad head fascia meets a rear shroud, while split column fairings leave the central travel path open. Screen, control and conduit openings can be incorporated into the appropriate cover sections.

Radiography-equipment interface view with a broad head shroud, separate control-box cover and column travel zone.

Radiography assembly reference for the head shroud, control-box cover and column fairings. We mold the specified exterior sections; screens, imaging hardware and the moving column are separate.

Radiography cover components

Broad head fascia

Broad head fascia

A wide, gently curved front fascia surrounds the central display opening and includes a horizontal panel joint.

Head rear shroud

Head rear shroud

The rear head cover comes in separate sections for service access, with cutouts along the lower edge for conduits.

Independent control-box cover

Independent control-box cover

This smaller enclosure for the control box has its own screen and rotary-control openings, separate from the head cover.

Split column fairings

Split column fairings

Side fairings cover the fixed column edges and leave the central travel path clear.

Customize the radiography covers

Head-cover molding

The head's front curvature and rear-cover depth can follow the imaging assembly's exterior outline.

Openings and motion clearances

Fairing edges leave clearance for column movement, and local cutouts allow conduits to pass between the covered assemblies.

Panel joints and surface appearance

Fixing areas and edge returns are made at each panel joint, with color and gloss matched across the set.

Radiography cover details

Head size and return depthHead width and height describe the fascia alone, excluding the separate lower attachment. The local L section measures return depth from the outer front-face plane to the free rear edge.Head widthHead heightReturn depth

Head size and return depth

Head width and height describe the fascia alone, excluding the separate lower attachment. The local L section measures return depth from the outer front-face plane to the free rear edge.

Separated radiography head fascia and rear cover, two column fairings and lower control enclosure with screen and control openings

Head, column and control covers

The cover set combines a head fascia and rear cover, two column fairings and a smaller control-box shell, with openings for the screen, controls and conduits.

All Medical Housings

FRP Digital Radiography Housing

Radiography-equipment interface view with a broad head shroud, separate control-box cover and column travel zone.

Radiography assembly reference for the head shroud, control-box cover and column fairings. We mold the specified exterior sections; screens, imaging hardware and the moving column are separate.