Factory Equipment & Ventilation
Keep routine servicing practical around factory ventilation and equipment. We make custom FRP cowlings, covers and ductwork with construction suited to the stated exposure and sections that open or come away for the planned maintenance tasks.

Where it is used
A fan inlet fitted around working plant
Replacing a fan inlet in an existing factory means fitting new parts around equipment that is already in place. The cowling must match the fan assembly, the duct has to avoid columns and nearby machinery, and both need removable connections for maintenance.
- Inlet profile, grille fixings and rotating-part clearance follow the fan supplier's assembly drawing.
- Duct joints and supports must leave room to reach and remove the service connections.
- The duct route must keep the maintenance aisle and equipment access open.
Our approach
Fit the plant and its maintenance routine
Fit the inlet and guard to the fan assembly
We work from the fan supplier's inlet section, rear mounting face and grille drawing. The cowling rim and fixings are placed so fasteners can be reached and the guard removed, while the equipment frame carries the motor and rotor.
The inlet fits the fan assembly, with access to remove the separately supplied guard.

Build a removable section into the duct route
From the plant survey we set the elbows, flange orientation and the removable duct length. Each section is checked against its support, its fastener access and the space needed to lift it clear during maintenance.
The layout identifies the removable duct section and the space needed to handle it.

Check the material and the first fit
The gas, temperature and cleaning conditions guide the cowling material specification. Ductwork is also specified for the stated pressure or vacuum. A first-part fit check on the reference assembly checks the mounting face and connections before repeat production.
The approved sample and component specification give repeat parts a common reference.
What we can supply
Supplied parts and site work
Inlet cowling and prepared joints
The cowling comes with the specified rim and mounting preparations. Duct sections carry the listed flanges and bends, with each connection position marked.
Sections prepared for service and replacement
The agreed removable lengths and cover sections are identified in the component set. Fit records preserve their connection and mounting details for the plant's maintenance team and any later repeat parts.
Equipment and site work
The equipment supplier remains responsible for fan operation and acceptance. Motors, rotors, guards, structural supports, installation and system commissioning are included only where listed separately.
Components for equipment and extraction
Fan housings and extraction work
- A fan housing that fits the rotor, guard and frame.
The inlet profile and mounting areas follow the fan assembly, with access for removing the guard.
- Duct sections prepared for the surveyed extraction route.
Bends, flange orientations and joint positions follow the equipment connections and site handling limits.